Review




Structured Review

Stryker surpass evolve device
Surpass Evolve Device, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surpass+evolve+device/evolve/10__3171_slash_case25930-40-4-7
Average 86 stars, based on 1 article reviews
surpass evolve device - by Bioz Stars, 2026-09
86/100 stars

Images

Related Articles

other:

Article Title: Intravenous cangrelor as rescue therapy for acute thrombosis in neuroendovascular procedures: illustrative cases
Article Snippet: A 5 × 15–mm Surpass Evolve device (Stryker) was deployed across the aneurysm neck.

Article Title: Neurointerventional procedures using sheathless 8 Fr Optimo balloon guide catheter via transradial access: A single-center experience with 100 cases
Article Snippet: Representative case of flow diversion for a large cavernous segment aneurysm of the internal carotid artery (ICA) via transradial access (TRA) using a sheathless 8 Fr Optimo balloon guide catheter (BGC). (A) Preoperative magnetic resonance angiography demonstrating significant tortuosity of the right common carotid artery. (B, C) Sheathless insertion of an 8 Fr Optimo BGC through the right radial artery. (D–F) Successful navigation of the BGC to the proximal cervical segment of the right ICA. (G) Angiography showing a large, wide-necked aneurysm at the cavernous segment of the ICA. (H–J) Flow diversion was successfully performed using a Surpass Evolve device (Stryker, Fremont, CA, USA).

Article Title: Intravenous cangrelor as rescue therapy for acute thrombosis in neuroendovascular procedures: illustrative cases
Article Snippet: A 5 × 15–mm Surpass Evolve device (Stryker) was deployed across the aneurysm neck.



Similar Products

86
Stryker surpass evolve device
Surpass Evolve Device, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surpass+evolve+device/evolve/10__3171_slash_case25930-40-4-7
Average 86 stars, based on 1 article reviews
surpass evolve device - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Stryker single surpass evolve device
Single Surpass Evolve Device, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surpass+evolve+device/evolve/pmc12611743-1705-14-18
Average 86 stars, based on 1 article reviews
single surpass evolve device - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Stryker surpass evolve devices
Surpass Evolve Devices, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surpass+evolve+device/devices+evolve+surpass/pmc12573315-68-16-19
Average 86 stars, based on 1 article reviews
surpass evolve devices - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Stryker surpass evolve embolization device
Stage 1: Preoperative diagnostic cerebral angiography demonstrating anterior-posterior (AP) (a) and lateral (b) projections of the 4-mm right A1 segment aneurysm (black arrowheads). Middeployment lateral unsubtracted (c) view of PED Flex deployment (black arrowhead) and intermediate access catheter, Catalyst5. Roadmap (d) view following PED Flex deployment across the neck of the aneurysm (black arrowhead). Postoperative AP (e) projection of the PED (red arrowhead) deployed across the neck of the aneurysm, jailing the right MCA (blue arrowhead demonstrating patency of right MCA). Five-year follow-up angiogram AP (f) and lateral (g) view demonstrating complete aneurysm obliteration (white arrowhead) and reduced MCA (blue arrowhead) filling with no in-stent thrombosis, displacement, pseudoaneurysm, or dissection in the parent vessel, and (h) robust MCA pial collateralization from the ACA. PED Flex: Pipeline <t>Embolization</t> Device Flex.
Surpass Evolve Embolization Device, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surpass+evolve+device/surpass+intracranial+aneurysm+embolization+system/pmc11344899-76-5-3
Average 90 stars, based on 1 article reviews
surpass evolve embolization device - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Stryker surpass evolve flow diverter device
Stage 1: Preoperative diagnostic cerebral angiography demonstrating anterior-posterior (AP) (a) and lateral (b) projections of the 4-mm right A1 segment aneurysm (black arrowheads). Middeployment lateral unsubtracted (c) view of PED Flex deployment (black arrowhead) and intermediate access catheter, Catalyst5. Roadmap (d) view following PED Flex deployment across the neck of the aneurysm (black arrowhead). Postoperative AP (e) projection of the PED (red arrowhead) deployed across the neck of the aneurysm, jailing the right MCA (blue arrowhead demonstrating patency of right MCA). Five-year follow-up angiogram AP (f) and lateral (g) view demonstrating complete aneurysm obliteration (white arrowhead) and reduced MCA (blue arrowhead) filling with no in-stent thrombosis, displacement, pseudoaneurysm, or dissection in the parent vessel, and (h) robust MCA pial collateralization from the ACA. PED Flex: Pipeline <t>Embolization</t> Device Flex.
Surpass Evolve Flow Diverter Device, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surpass+evolve+device/surpass+evolve+flow+diverter/pmc11344899-32-14-19
Average 90 stars, based on 1 article reviews
surpass evolve flow diverter device - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Stryker flow diverting device stryker surpass evolve (se)
Stage 1: Preoperative diagnostic cerebral angiography demonstrating anterior-posterior (AP) (a) and lateral (b) projections of the 4-mm right A1 segment aneurysm (black arrowheads). Middeployment lateral unsubtracted (c) view of PED Flex deployment (black arrowhead) and intermediate access catheter, Catalyst5. Roadmap (d) view following PED Flex deployment across the neck of the aneurysm (black arrowhead). Postoperative AP (e) projection of the PED (red arrowhead) deployed across the neck of the aneurysm, jailing the right MCA (blue arrowhead demonstrating patency of right MCA). Five-year follow-up angiogram AP (f) and lateral (g) view demonstrating complete aneurysm obliteration (white arrowhead) and reduced MCA (blue arrowhead) filling with no in-stent thrombosis, displacement, pseudoaneurysm, or dissection in the parent vessel, and (h) robust MCA pial collateralization from the ACA. PED Flex: Pipeline <t>Embolization</t> Device Flex.
Flow Diverting Device Stryker Surpass Evolve (Se), supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surpass+evolve+device/surpass+evolve+flow+diverter/pm37170614-48-15-16
Average 90 stars, based on 1 article reviews
flow diverting device stryker surpass evolve (se) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Stryker fd device surpass evolve
Stage 1: Preoperative diagnostic cerebral angiography demonstrating anterior-posterior (AP) (a) and lateral (b) projections of the 4-mm right A1 segment aneurysm (black arrowheads). Middeployment lateral unsubtracted (c) view of PED Flex deployment (black arrowhead) and intermediate access catheter, Catalyst5. Roadmap (d) view following PED Flex deployment across the neck of the aneurysm (black arrowhead). Postoperative AP (e) projection of the PED (red arrowhead) deployed across the neck of the aneurysm, jailing the right MCA (blue arrowhead demonstrating patency of right MCA). Five-year follow-up angiogram AP (f) and lateral (g) view demonstrating complete aneurysm obliteration (white arrowhead) and reduced MCA (blue arrowhead) filling with no in-stent thrombosis, displacement, pseudoaneurysm, or dissection in the parent vessel, and (h) robust MCA pial collateralization from the ACA. PED Flex: Pipeline <t>Embolization</t> Device Flex.
Fd Device Surpass Evolve, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/surpass+evolve+device/surpass+evolve+fd/pmc08960056-79-17-19
Average 90 stars, based on 1 article reviews
fd device surpass evolve - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Stage 1: Preoperative diagnostic cerebral angiography demonstrating anterior-posterior (AP) (a) and lateral (b) projections of the 4-mm right A1 segment aneurysm (black arrowheads). Middeployment lateral unsubtracted (c) view of PED Flex deployment (black arrowhead) and intermediate access catheter, Catalyst5. Roadmap (d) view following PED Flex deployment across the neck of the aneurysm (black arrowhead). Postoperative AP (e) projection of the PED (red arrowhead) deployed across the neck of the aneurysm, jailing the right MCA (blue arrowhead demonstrating patency of right MCA). Five-year follow-up angiogram AP (f) and lateral (g) view demonstrating complete aneurysm obliteration (white arrowhead) and reduced MCA (blue arrowhead) filling with no in-stent thrombosis, displacement, pseudoaneurysm, or dissection in the parent vessel, and (h) robust MCA pial collateralization from the ACA. PED Flex: Pipeline Embolization Device Flex.

Journal: SAGE Open Medical Case Reports

Article Title: Flow diversion of cerebral aneurysms in Type I osteogenesis imperfecta: A case report of the first two treatments in humans

doi: 10.1177/2050313X241274243

Figure Lengend Snippet: Stage 1: Preoperative diagnostic cerebral angiography demonstrating anterior-posterior (AP) (a) and lateral (b) projections of the 4-mm right A1 segment aneurysm (black arrowheads). Middeployment lateral unsubtracted (c) view of PED Flex deployment (black arrowhead) and intermediate access catheter, Catalyst5. Roadmap (d) view following PED Flex deployment across the neck of the aneurysm (black arrowhead). Postoperative AP (e) projection of the PED (red arrowhead) deployed across the neck of the aneurysm, jailing the right MCA (blue arrowhead demonstrating patency of right MCA). Five-year follow-up angiogram AP (f) and lateral (g) view demonstrating complete aneurysm obliteration (white arrowhead) and reduced MCA (blue arrowhead) filling with no in-stent thrombosis, displacement, pseudoaneurysm, or dissection in the parent vessel, and (h) robust MCA pial collateralization from the ACA. PED Flex: Pipeline Embolization Device Flex.

Article Snippet: The Surpass Evolve (Stryker Neurovascular) embolization device was selected for the second intervention for multiple reasons.

Techniques: Diagnostic Assay, Dissection